Instrumentation
 
6 Core overall Shielded Unarmoured
6 Core overall Shielded Armoured


Multicore PVC/PE Insulated Shielded Cable
:

Dimensions of 0.5 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd.

Armd. Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.00

 

10.5

 

12.0

 

14.5

17.0

17.0

18.5

18.5

Size of G.!. Armour mm

 

0.90

 

0.90

 

0.90

 

4 x 0.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

7.80

 

12.3

 

13.8

 

16.1

 

18.6

 

20.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

1.10

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.50

10.6

11.0

15.10

12.5

16.6

15.0

19.5

19.8

22.0

22.0

23.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000


Dimensions of 1.00 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables.


Number of Cores

TWO

THREE

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

 

0.80

 

0.80

Diameter over innersheath mm

 

6.60

 

7.00

 

7.60

 

9.10

 

1t:6

 

12.0

Size of G.!. Armour mm

 

0.90

 

0.90

 

0.90

 

0.90

 

0.90

 

0.90

Diameter over armour mm

 

8.40

 

8.80

 

9.40

 

10.9

 

13.4

 

13.8

Nom. Thickness of oversheath mm

0.90

1.40

0.90

1.40

0.90

1.40

1.00

1.40

1.10

1.40

1.10

1.40

Nom. overall diameter mm

6.80

11.2

7.20

11.6

7.80

12.2

9.50

13.7

12.2

16.2

12.6

16.6

Normal Delivery Length +/-5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000


Dimensions of 1.50 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables.

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

 

TEN

 

TWELVE

Cable type

Unarmd.

Armd.

Unarmd. Armd.

Unarmd. Armd,

Unarmd.

Armd.

Unarrnd.

Armd.

Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.80

 

10.5

 

13.0

 

16.5

18.5

18.5

20.5

20.5

Size of G.I. Armour mm

 

0.90

 

0.90

 

0.90

 

4xO.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

8.60

 

12.8

 

14.8

 

18.1

 

20.8

 

22.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.10

1.40

.1.10

1.60

1.40

1.60

1.40

1.60

Nom. overall diameter mm

7.00

11.40

12.0

15.6

14.5

17.6

17.5

21.5

22.0

23.5

23.5

25.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

500


PVC/PE Insulated Individual
& Overall Shielded Paired Cables:

Table details of conductors and insulation thickness
Norminal area of condector in sq m.m Constrction details number/daimeter mm Max resistance in o hm/km at 20 dag Multicore/multipair Thikness of insutation in mm average/ minimum Nominal core dimeter mm
0.50
7/0.30
39.0
39.7
0.6
0.44
2.20
0.75
7/0.37
26.0
26.5
0.6
0.44
2.50
1.00
7/0.43
18.1
18.4
0.6
0.44
2.60
1.50
7/0.53
12.1
12.4
0.6
0.44
2.60

NOTE : 1. Fortinned copper conductor ,the above resistance values will be higher by 0.6 %
           2. As per International standards, which is also adopted by BIS and BS, the size of conductor is decided by its resistance only. The constructions of the conductor                 mentioned above and henceforth in this catalogue, are only indicative in nature. They may vary within the prescribed limits if any, laid by the standards.

4 Pair overall Shielded Unarmoured
4 Pair overall Shielded Armoured
PVC/PE Insulated Overall Shielded Paired Cables:

Dimensions of 0.75 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables.


Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd.

Armd.

Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd.

Armd.

Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.60

 

10.0

 

12.5

 

15.0

17.5

17.5

19.0

19.0

Size of G.I. Armour mm

 

0.90

 

0.90

 

0.90

 

4 xO.8

 

4 xO.8

 

4xO.8

Diameter over armour mm

 

8.40

 

11.8

 

14.3

 

16.6

 

19.1

 

20.6

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

1.10

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.80

11'.2

11.0

14.6

13.0

17.1

16.0

20.0

20.3

22.5

22.50

24.0

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

1000

500

500


Dimensions of 1.00 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables.

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

 

TEN

 

TWELVE

Cable type

Unarmd.

Armd.

Unarmd. Armd.

Unarmd. Armd,

Unarmd.

Armd.

Unarrnd.

Armd.

Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.80

 

10.5

 

13.0

 

16.5

18.5

18.5

20.5

20.5

Size of G.I. Armour mm

 

0.90

 

0.90

 

0.90

 

4xO.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

8.60

 

12.8

 

14.8

 

18.1

 

20.8

 

22.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.10

1.40

.1.10

1.60

1.40

1.60

1.40

1.60

Nom. overall diameter mm

7.00

11.40

12.0

15.6

14.5

17.6

17.5

21.5

22.0

23.5

23.5

25.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

500


Dimensions of 1.50 sq mm multicore PVC/PE insulated Alu polyester tapped shield cables.

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

 

TEN

 

TWELVE

Cable type

Unarmd.

Armd.

Unarmd. Armd.

Unarmd. Armd,

Unarmd.

Armd.

Unarrnd.

Armd.

Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.80

 

10.5

 

13.0

 

16.5

18.5

18.5

20.5

20.5

Size of G.I. Armour mm

 

0.90

 

0.90

 

0.90

 

4xO.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

8.60

 

12.8

 

14.8

 

18.1

 

20.8

 

22.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.10

1.40

.1.10

1.60

1.40

1.60

1.40

1.60

Nom. overall diameter mm

7.00

11.40

12.0

15.6

14.5

17.6

17.5

21.5

22.0

23.5

23.5

25.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

500


PVC/PE Insulated Individual
& Overall Shielded Paired Cables:

Table details of conductors and insulation thickness
Norminal area of condector in sq m.m Constrction details number/daimeter mm Max resistance in o hm/km at 20 dag Multicore/multipair Thikness of insutation in mm average/ minimum Nominal core dimeter mm
0.50
7/0.30
39.0
39.7
0.6
0.44
2.20
0.75
7/0.37
26.0
26.5
0.6
0.44
2.50
1.00
7/0.43
18.1
18.4
0.6
0.44
2.60
1.50
7/0.53
12.1
12.4
0.6
0.44
2.60

NOTE : 1. Fortinned copper conductor ,the above resistance values will be higher by 0.6 %
           2. As per International standards, which is also adopted by BIS and BS, the size of conductor is decided by its resistance only. The constructions of the conductor                 mentioned above and henceforth in this catalogue, are only indicative in nature. They may vary within the prescribed limits if any, laid by the standards.

Pair Individual & Overall Shielded Armoured Cable


Dimensions of 0.5 sq mm multicore PVC/PE insulated Alu polyester tapped Over all Shielded Paired Cables.


Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd.

Armd. Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.00

 

10.5

 

12.0

 

14.5

17.0

17.0

18.5

18.5

Size of G.!. Armour mm

 

0.90

 

0.90

 

0.90

 

4 x 0.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

7.80

 

12.3

 

13.8

 

16.1

 

18.6

 

20.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

1.10

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.50

10.6

11.0

15.10

12.5

16.6

15.0

19.5

19.8

22.0

22.0

23.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500


PVC/PE Insulated Individual & Overall Cable:

Dimnsions of 0.75 sq mm multicore PVC/PE insulated Alu polyester tapped Over all Shielded Paired Cables

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd.

Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.60

 

11.5

 

13.0

 

16.0

18.5

18.5

20.0

20.0

Size of G.I. Armour mm

 

0.90

 

0.90

 

0.90

 

4xO.8

 

4xO.8

 

4 xO.8

Diameter over armour mm

 

8.40

 

13.3

 

14.8

 

17.6

 

20.1

 

21.6

Nom.Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

UO

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.80

11.2

12.0

16.1

13.5

17.6

16.7

21.0

21.5

23.5

23.5

25.0

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

500




Dimnsions of 1.00 sq mm multicore PVC/PE insulated Alu polyester tapped Over all Shielded Paired Cables

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd.

Armd. Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.00

 

10.5

 

12.0

 

14.5

17.0

17.0

18.5

18.5

Size of G.!. Armour mm

 

0.90

 

0.90

 

0.90

 

4 x 0.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

7.80

 

12.3

 

13.8

 

16.1

 

18.6

 

20.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

1.10

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.50

10.6

11.0

15.10

12.5

16.6

15.0

19.5

19.8

22.0

22.0

23.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500


Dimnsions of 1.50 sq mm multicore PVC/PE insulated Alu polyester tapped Over all Shielded Paired Cables

Number of Pairs

ONE

 

TWO

 

FOUR

SIX

TEN

 

TWELVE

Cable type

Unarmd. Armd. Unarmd. Armd.

Unarmd. Armd. Unarmd. Armd.

Unarmd.

Armd. Unarmd.

Armd.

Nom. Thickness of innersheath mm

 

0.80

 

0.80

 

0.80

 

0.80

1.00

1.00

1.00

1.00

Diameter over innersheath mm

 

6.00

 

10.5

 

12.0

 

14.5

17.0

17.0

18.5

18.5

Size of G.!. Armour mm

 

0.90

 

0.90

 

0.90

 

4 x 0.8

 

4xO.8

 

4xO.8

Diameter over armour mm

 

7.80

 

12.3

 

13.8

 

16.1

 

18.6

 

20.1

Nom. Thickness of oversheath mm

0.90

1.40

1.00

1.40

1.00

1.40

1.10

1.60

1.40

1.60

1.60

1.60

Nom. overall diameter mm

6.50

10.6

11.0

15.10

12.5

16.6

15.0

19.5

19.8

22.0

22.0

23.5

Normal Delivery Length +/- 5% Mtr

1000

1000

1000

1000

1000

1000

1000

1000

1000

500

500

500

 

1   I   2   I   3   I   4   I    5